Corner Spacer

Corner Spacer

Aluminium Corner Spacer designed to add strength to >90 degree corners. Corners can be vulnerable points in a security barrier. This accessory fits over Vandgard’s spindle to accurately hold corners together and maintain enough clearance to rotate freely. Used in conjunction with a Support Bracket ( Part No Supp01 )   Simple to fix   Corrosion free aluminium   Locks corners   In Stock!   Next Day Delivery!         Specification:   Corner Spacer ex BS6082 Aluminium Tube 275mm long x 27mm internal diameter closed and flattened one end and drilled with 27mm hole   Fixing:
Corners are securely locked together with Corner spacers positioned 150-300mm back from the end of a run of Vandgard Anti Climb Guard together with an extra support bracket. Supports should be adjusted to support Vandgard centrally over walls and fences with a clearance not exceeding 50mm. Bolted, clamped or welded to fences gates walls and soffits. Vandgard must be supported at 2 metre intervals and at corners.   NOTE: Corners less than 60degrees may be easily formed using a 25mm plumber’s pipe bending machine on the spindle.…

Model
CORN01
Double Row cranked support bracket

Double Row cranked support bracket

Galvanised steel support bracket designed to fit most double row applications including Walls Fences Gates & Steel palisade fencing. A vertical support bracket . Fixed vertically on walls etc. or horizontally under a soffit or on a flat ledge.   Simple to fix with 8mm fixings Spin Galvanised against corrosion Strong 6mm steel. 
  Laser cut and Folded for strength   Description:
Galvanised steel support bracket   Specification:   Ex 40 x 6 Mild steel bar slotted twice to receive 8mm fixing bolts ( bolts not supplied) and drilled with 29mm diameter hole to support Vandgard Anti-Climb axle. Galvanised after manufacture to (BS EN ISO 1461) Laser cut and folded.
    Fixing:
Supports should be adjusted to support Vandgard centrally over walls or to the back of fences with a clearance not exceeding 50mm. Bolted, clamped or welded to fences gates walls and soffits. Vandgard must be supported at 2 metre intervals.
(Designed to support Vandgard part nos VS05 and VSC05)   For steel palisade fencing, supports must be fixed to the pales at 2metre intervals. Usually cranked to the rear and fixed between the horizontal rail and vertical pale with one extra long 8mm fixing rivet .Use the existing fixing holes .
    Finish:
Standard finish means natural, self-colour galvanised metal finish (i.e. not coated or painted)    …

Model
SUPP09
Dual Zone Analyser GD5000

Dual Zone Analyser GD5000

The GD5000 analyser, combined with Alpha Sensor, is a stand alone perimeter intruder detection device. It exploits the precision Alpha Sensor technology by processing the analogue signal generated by an intrusion attempt on the perimeter fence For use with the Defensor system, it is designed to pick up vibrations as soon as any contact is made with the fence. A security system which incorporates Defensor will alarm as soon as an attack starts. During the time taken to breach the fence, the area of attack can be located, security staff mobilised and CCTV, lights and sirens activated. This means that the control of the situation stays with the security service and the attack can often be prevented.…

Model
ACOU02
End Bracket

End Bracket

End Bracket for Rota 10.10 20.20 Spike Above RSJ Post (J4/04117/2) Galvanized (Palisade End)…

Model
End Bracket
Extra Joining Spigot

Extra Joining Spigot

Aluminium joining spigot. This accessory is designed to easily join together two lengths of Vandgard shaft in one continuous run. The spigot is made slightly larger than the internal diameter of the shaft. Using a pair of ‘Mole’ or ‘Vice’ grips the spigot is squeezed and inserted halfway into the shaft so that it springs open tightly in place inside the shaft.   Simple to fix   Corrosion free aluminium   In Stock!   Next Day Delivery!         Specification:   Aluminium spigot extruded section to patented design 150mm long. Ex BS 6082 aluminium. Designed for use with Vandgard anti-climb system and shaft (product code vs05 contains one spigot per 2metres))   Fixing:
Using grips the sprung spigot is compressed sufficiently to fit inside the tubular aluminium shaft and then hammered in for approximately 75mm ensuring a tight fit. The process is repeated with further sections of shaft at maximum 2 metre intervals to provide a smooth and continuous spindle.   Note: When fixing a ‘Rotaguard’ acoustic alarm system, the sensor should be fed through the spindle during the fixing process.…

Model
SPIGBAC01
Extra Top Rail Shaft 2m

Extra Top Rail Shaft 2m


2m Top Rail Shaft 41.5mm Diameter  Supplied in 2m lengths . 41.5mm dia x 2mm wall thickness. For use with Rota spike Security topping system 
Specifications
Width:41.5mm
Length:2000mm…

Five Pair Feeder Cable

Five Pair Feeder Cable

For further infrmation, please download the Technical Information PDFs Five Pair Feeder Cable…

Model
ACOU08
G19 End Boss

G19 End Boss
G19 End Boss includes fitted Oilite Bearing Oilite Bearing Code No. AI162024 I/D to suit 1" Dia. S.S. Tube 1 Pipe Clamp Spinner Assembly 1 1" O/D x 0.081 w/t. St. Steel Tube...see more

  G19 End Boss includes fitted Oilite Bearing Oilite Bearing Code No. AI162024  I/D to suit 1" Dia. S.S. Tube  1 Pipe Clamp Spinner Assembly 1 1" O/D x 0.081 w/t. St. Steel Tube   …

Model
G19EB
G19 End Support 170 x 215mm Long - End

G19 End Support 170 x 215mm Long - End

170mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 170mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
end 170x215
G19 End Support 175x 215mm Long - End

G19 End Support 175x 215mm Long - End

175@ 215mm Long - END   SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 175mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
End175x215
G19 End Support 355X215mm Long - End

G19 End Support 355X215mm Long - End

355@ 215mm Long - END SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 355mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
end355215
G19 End Support 425x350

G19 End Support 425x350

425mm Dia @ 350mm Long - END Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 426mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
476350END
G19 End Support 600x350

G19 End Support 600x350

Spinner assembly to suit NB80 - NB300 Pipe Strap As G19 Specification…

Model
624350END
G19 End Support 650x350

G19 End Support 650x350


650mm Dia @ 350mm Long - End Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 650mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
640x350END
G19 inter Support 170x215

G19 inter Support 170x215

170mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 170mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
inter 170x215
G19 INTER Support 175x 215mm Long - INTER

G19 INTER Support 175x 215mm Long - INTER

175@ 215mm Long - INTER  SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 175mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
End175x215
G19 Inter Support 425x350

G19 Inter Support 425x350
Intermediate Spinner assembly to suit NB80 - NB300 Pipe Strap As G19 Specification...see more

425mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 426mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
426350INTER
G19 Inter Support 650x350

G19 Inter Support 650x350

650mm Dia @ 350mm Long - Intermediate Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 650mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
640x350INTER
Gate Loop Kit - Hinged Gates GDGLK-A

Gate Loop Kit - Hinged Gates GDGLK-A
Most sites have gates of one form or another which interrupt the sensor zone and as such need to be protected. The gap between fence and gate is bridged using a GDGLK-A/B Gate Loop Kit for swing gates or a GDGLK-C for sliding gates....see more

Gate Loop Kit for Hinged Gates Most sites have gates of one form or another which interrupt the sensor zone and as such need to be protected. The gap between fence and gate is bridged using a GDGLK-A/B Gate Loop Kit for swing gates or a GDGLK-C for sliding gates. The kits comprise of two of the boxes as shown in Figure 5 connected by a prewired flexible coiled cable which carries the sensor signal to and from the gate. This non sensitive cable is designed to withstand the flexing caused by the gate opening and closing. The box is fitted with two glands, the use of which is dependent on the gate type and the positioning of the box. Refer to the sensor installation manual QA189 for further details. 1. Terminate the ends of the sensor as described in Section 2. 2. Loosen the glands on the boxes and pass the terminated end into the box so sufficient length is available on the tails to be wired into the terminal blocks. Ensure that the sensor is passed through the correct gland to correspond to the position of the terminal block, i.e. through the left gland to connect to the left terminal block at the left hand side of the gate and vice versa at the right hand side. Tighten the glands by hand ensuring the rubber sealing ring grips the sensor jacket and not the HDPE tubes. 3. Position the boxes just above the line of the sensor to allow rain water to run away from the glands and fix to the fence using the mounting kit provided. The mounting bar is located across the diagonals of the box and is fixed in place by dropping the screws provided into the large holes at the corner of the box and screwing these into the mounting bar placed on the other side of the fence. If fixing the box to a wall or other solid surface the mounting bar can be dispensed with and the box fitted directly to the Pre-wired by Geoquip GDALPHA sensor from analyser GQFC-9 dead cable to other side of gate Pre-wired cable to box on gate GDGLK GATE LOOP KITS 8 surface with appropriate fixings. 4. Connect the sensor tails to the terminal blocks on the PCB. 5. Replace the box lids, taking care not to over tighten the lid screws and verify that the tamper switch in each box operates by listening for the click of the switch action as the lid is screwed down. In order to attain a weatherproof seal the lid must be replaced with the correct orientation, i.e. with the chamfered edges vertical.…

Model
GDGLK-A/B/C
GQCOMBO ACCESSORY BOX

GQCOMBO ACCESSORY BOX
GQCOMBO ACCESSORY BOX Terminates the ends of a suitable length of sensor as described Replace the blanking plug with the appropriate plastic PG9 gland which comes with the GQCOMBO....see more

GQCOMBO ACCESSORY BOX 5 Figure 4 Terminate the ends of a suitable length of sensor as described in Section 2. 1. Replace the blanking plug with the appropriate plastic PG9 gland which comes with the GQCOMBO. Remove all the links fitted to the PCB. 2. Loosen the glands on the junction boxes and pass the terminated end into the box so sufficient length is available on the tails to be wired into the terminal blocks. Ensure that the sensor is passed through the correct gland to correspond to the position of the terminal block, i.e. through the left gland to connect to the left terminal block at the right hand end of the cable and vice versa at the left end. Tighten the glands by hand so that the rubber sealing ring grips the sensor jacket and not the HDPE tubes. 3. Connect the sensor tails to the terminal blocks on the PCB. Figure 4 shows sensor wired to the left hand terminal block of the GQCOMBO box. 4. Cut off the damaged section of sensor from the fence and terminate the ends of the remaining sensor in the same manner as above. To ensure that no moisture enters the open ends, this step should only be carried out immediately prior to fixing the new section. 5. Position the boxes just above the line of the sensor to allow rain water to run away from the glands and fix to the protected surface using the mounting kit provided. The mounting bar is located across the diagonals of the box and is fixed in place by dropping the screws provided into the large holes at the corner of the box and screwing these into the mounting bar placed on the other side of the fence. If fixing the box to a wall or other solid surface the mounting bar can be dispensed with and the box fitted directly to the surface with appropriate fixings. Ensure that the new section of sensor is at the same height and tension the original. GQCOMBO ACCESSORY BOX 6 6. Connect the tails of the existing sensor to the junction box terminal blocks on the PCB. 7. Replace the box lids, taking care not to over tighten the lid screws and verify that the tamper switch in each box operates by listening for the click of the switch action as the lid is screwed down. In order to attain a weatherproof seal the lid must be replaced with the correct orientation. 8. Retest the entire zone to ensure that the sensor detects simulated impact and sustained attacks. …

Model
ACOU03