JavaScript seems to be disabled in your browser.

You must have JavaScript enabled in your browser to utilize the functionality of this website. Click here for instructions on enabling javascript in your browser.

G19 End Boss

G19 End Boss
G19 End Boss includes fitted Oilite Bearing Oilite Bearing Code No. AI162024 I/D to suit 1" Dia. S.S. Tube 1 Pipe Clamp Spinner Assembly 1 1" O/D x 0.081 w/t. St. Steel Tube...see more

  G19 End Boss includes fitted Oilite Bearing Oilite Bearing Code No. AI162024  I/D to suit 1" Dia. S.S. Tube  1 Pipe Clamp Spinner Assembly 1 1" O/D x 0.081 w/t. St. Steel Tube   …

Model
G19EB
G19 End Support 170 x 215mm Long - End

G19 End Support 170 x 215mm Long - End

170mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 170mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
end 170x215
G19 End Support 175x 215mm Long - End

G19 End Support 175x 215mm Long - End

175@ 215mm Long - END   SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 175mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
End175x215
G19 End Support 355X215mm Long - End

G19 End Support 355X215mm Long - End

355@ 215mm Long - END SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 355mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
end355215
G19 End Support 425x350

G19 End Support 425x350

425mm Dia @ 350mm Long - END Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 426mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
476350END
G19 End Support 600x350

G19 End Support 600x350

Spinner assembly to suit NB80 - NB300 Pipe Strap As G19 Specification…

Model
624350END
G19 End Support 650x350

G19 End Support 650x350


650mm Dia @ 350mm Long - End Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 650mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
640x350END
G19 inter Support 170x215

G19 inter Support 170x215

170mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 170mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
inter 170x215
G19 INTER Support 175x 215mm Long - INTER

G19 INTER Support 175x 215mm Long - INTER

175@ 215mm Long - INTER  SINGLE ROW Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 175mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
End175x215
G19 Inter Support 425x350

G19 Inter Support 425x350
Intermediate Spinner assembly to suit NB80 - NB300 Pipe Strap As G19 Specification...see more

425mm Dia @ 350mm Long - IntermediateIncludes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 426mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
426350INTER
G19 Inter Support 650x350

G19 Inter Support 650x350

650mm Dia @ 350mm Long - Intermediate Includes Oilite bearing St/st housing, Laser cut, fold and weld. Clamp to suit 650mm pipe Nylok Nuts Bolts + allow for 10mm Neoprene lining…

Model
640x350INTER
Gate Loop Kit - Hinged Gates GDGLK-A

Gate Loop Kit - Hinged Gates GDGLK-A
Most sites have gates of one form or another which interrupt the sensor zone and as such need to be protected. The gap between fence and gate is bridged using a GDGLK-A/B Gate Loop Kit for swing gates or a GDGLK-C for sliding gates....see more

Gate Loop Kit for Hinged Gates Most sites have gates of one form or another which interrupt the sensor zone and as such need to be protected. The gap between fence and gate is bridged using a GDGLK-A/B Gate Loop Kit for swing gates or a GDGLK-C for sliding gates. The kits comprise of two of the boxes as shown in Figure 5 connected by a prewired flexible coiled cable which carries the sensor signal to and from the gate. This non sensitive cable is designed to withstand the flexing caused by the gate opening and closing. The box is fitted with two glands, the use of which is dependent on the gate type and the positioning of the box. Refer to the sensor installation manual QA189 for further details. 1. Terminate the ends of the sensor as described in Section 2. 2. Loosen the glands on the boxes and pass the terminated end into the box so sufficient length is available on the tails to be wired into the terminal blocks. Ensure that the sensor is passed through the correct gland to correspond to the position of the terminal block, i.e. through the left gland to connect to the left terminal block at the left hand side of the gate and vice versa at the right hand side. Tighten the glands by hand ensuring the rubber sealing ring grips the sensor jacket and not the HDPE tubes. 3. Position the boxes just above the line of the sensor to allow rain water to run away from the glands and fix to the fence using the mounting kit provided. The mounting bar is located across the diagonals of the box and is fixed in place by dropping the screws provided into the large holes at the corner of the box and screwing these into the mounting bar placed on the other side of the fence. If fixing the box to a wall or other solid surface the mounting bar can be dispensed with and the box fitted directly to the Pre-wired by Geoquip GDALPHA sensor from analyser GQFC-9 dead cable to other side of gate Pre-wired cable to box on gate GDGLK GATE LOOP KITS 8 surface with appropriate fixings. 4. Connect the sensor tails to the terminal blocks on the PCB. 5. Replace the box lids, taking care not to over tighten the lid screws and verify that the tamper switch in each box operates by listening for the click of the switch action as the lid is screwed down. In order to attain a weatherproof seal the lid must be replaced with the correct orientation, i.e. with the chamfered edges vertical.…

Model
GDGLK-A/B/C
GQCOMBO ACCESSORY BOX

GQCOMBO ACCESSORY BOX
GQCOMBO ACCESSORY BOX Terminates the ends of a suitable length of sensor as described Replace the blanking plug with the appropriate plastic PG9 gland which comes with the GQCOMBO....see more

GQCOMBO ACCESSORY BOX 5 Figure 4 Terminate the ends of a suitable length of sensor as described in Section 2. 1. Replace the blanking plug with the appropriate plastic PG9 gland which comes with the GQCOMBO. Remove all the links fitted to the PCB. 2. Loosen the glands on the junction boxes and pass the terminated end into the box so sufficient length is available on the tails to be wired into the terminal blocks. Ensure that the sensor is passed through the correct gland to correspond to the position of the terminal block, i.e. through the left gland to connect to the left terminal block at the right hand end of the cable and vice versa at the left end. Tighten the glands by hand so that the rubber sealing ring grips the sensor jacket and not the HDPE tubes. 3. Connect the sensor tails to the terminal blocks on the PCB. Figure 4 shows sensor wired to the left hand terminal block of the GQCOMBO box. 4. Cut off the damaged section of sensor from the fence and terminate the ends of the remaining sensor in the same manner as above. To ensure that no moisture enters the open ends, this step should only be carried out immediately prior to fixing the new section. 5. Position the boxes just above the line of the sensor to allow rain water to run away from the glands and fix to the protected surface using the mounting kit provided. The mounting bar is located across the diagonals of the box and is fixed in place by dropping the screws provided into the large holes at the corner of the box and screwing these into the mounting bar placed on the other side of the fence. If fixing the box to a wall or other solid surface the mounting bar can be dispensed with and the box fitted directly to the surface with appropriate fixings. Ensure that the new section of sensor is at the same height and tension the original. GQCOMBO ACCESSORY BOX 6 6. Connect the tails of the existing sensor to the junction box terminal blocks on the PCB. 7. Replace the box lids, taking care not to over tighten the lid screws and verify that the tamper switch in each box operates by listening for the click of the switch action as the lid is screwed down. In order to attain a weatherproof seal the lid must be replaced with the correct orientation. 8. Retest the entire zone to ensure that the sensor detects simulated impact and sustained attacks. …

Model
ACOU03